ANALYSIS OF BANDED STRUCTURES IN DUAL-PHASE STEELS

One steel sample showing banding dual phase structure is submitted for analysis. Detection and measurement of pearlitic-ferritic phases as well as ASTM E112 grain size was performed using a machine-learning algorithm specifically designed for dual-phase steels. This method greatly simplifies segmentation and is therefore more efficient especially on a large sample.

Analysis of banded structures in dual-phase steels | Clemex

Figure 1. Banded dual-phase structure viewed at 200X.

Analysis of banded structures in dual-phase steels | Clemex

Figure 2. Ferrite and pearlite automatically detected in red and green prior to area percent measurement.

Analysis of banded structures in dual-phase steels | Clemex

Figure 2. Grain boundaries are detected using the Ferrite-pearlite algorithm prior to ASTM E112 measurement.

CLEMEX SOLUTION FOR BANDING ANALYSIS

Clemex Vision image analysis software reliably detects ferritic and pearlitic phases and evaluates their banding according to ASTM E1268. Grain size as per ASTM E112 is also performed using the same software, calibrated with a NIST-traceable stage micrometer.

Analysis of banded structures in dual-phase steels | Clemex

RESULTS

ASTM E1258 banding and ASTM E112 grain size measurements are performed. Results are cumulated for automated statistics and graph generation. Final results can be printed directly from Clemex Vision. Raw data are linked to their respective objects and can be exported in Excel format.

Analysis of banded structures in dual-phase steels | Clemex
Analysis of banded structures in dual-phase steels | Clemex